At the recent Ho Chi Minh City Ophthalmology Conference 2026, Dr. Nguyen Phu Tung and Specialist Doctor I Tu Thanh Nu Thuyet Minh presented research evaluating the efficacy, safety, and stability of phakic ICL implantation in eyes with a natural crystalline lens.

Dr. Nguyen Phu Tung at the Ho Chi Minh City Ophthalmology Conference 2026
Dr. Nguyen Phu Tung Presents Research on Phakic ICL at HOOC5
Under the topic “Evaluation of the Treatment Outcomes of Phakic Intraocular Lens Implantation for High Myopia and Astigmatism in Phakic Eyes,” the study by Specialist Doctor I Từ Thanh Nữ Thuyết Minh and MSc. Dr. Nguyen Phu Tung focused on patients with high myopia and astigmatism, a group that may face limitations when considering laser refractive surgery.
According to the study, the V4c-generation ICL is considered a refractive surgery option capable of providing high-quality vision without removing corneal tissue. This is particularly relevant for patients with high levels of myopia or those who are not suitable candidates for corneal refractive surgery.
The study also highlighted an important yet sometimes overlooked technical factor: accurately measuring the horizontal corneal diameter (White-to-White – WTW) to support appropriate ICL sizing.
How Was the Study Conducted?
This was a prospective, non-comparative interventional clinical study conducted in patients aged 21–45 years who had an indication for and met the eligibility criteria for phakic ICL implantation to correct high myopia and astigmatism.

Dr. Nguyen Phu Tung at the Ho Chi Minh City Ophthalmology Conference 2026
Study participants were recruited at Sai Gon Ngoc Gia Tu Eye Hospital between March 2021 and February 2024.
The inclusion criteria were designed to ensure that patients met both refractive and anatomical requirements. Patients were required to have stable refraction for at least one year before surgery, as well as appropriate anatomical parameters, including anterior chamber depth, endothelial cell density, and an open anterior chamber angle.
Patients were followed for 12 months after surgery to evaluate the efficacy, safety, stability, and predictability of the procedure.
Efficacy of V4c ICL for High Myopia and Astigmatism
One of the key findings of the study was the postoperative visual acuity. Follow-up data showed that a significant proportion of patients achieved uncorrected distance visual acuity (UDVA) that was equivalent to or better than their preoperative corrected distance visual acuity (CDVA).
These findings suggest that V4c ICL has the potential to provide significant visual improvement for patients with high myopia and astigmatism.

Dr. Nguyen Phu Tung at the Ho Chi Minh City Ophthalmology Conference 2026
In addition to visual acuity, achieving the intended refractive target is another important criterion when evaluating refractive surgery. The study demonstrated a high degree of accuracy in correcting refractive errors, with postoperative refraction concentrated within the predetermined target range.
These results further support the role of Phakic ICL in treating high myopia and astigmatism, particularly in patients who are not suitable candidates for corneal laser refractive procedures.
Safety of ICL Surgery After 12 Months
Beyond visual outcomes, Dr. Nguyen Phu Tung’s research placed particular emphasis on postoperative safety parameters. One important factor in evaluating ICL safety is the Vault, which refers to the distance between the posterior surface of the ICL and the anterior surface of the crystalline lens. An appropriate Vault helps minimize potential risks associated with interaction between the ICL and intraocular structures.

Dr. Nguyen Phu Tung and Specialist Doctor I Tu Thanh Nu Thuyet Minh at the Ho Chi Minh City Ophthalmology Conference 2026

Dr. Nguyen Phu Tung at the Ho Chi Minh City Ophthalmology Conference 2026
The study found that the mean Vault was within the ideal physiological safety range. After 12 months of follow-up, no serious complications such as elevated intraocular pressure, cataract formation, or cases requiring ICL replacement were reported.
Notably, the rate of endothelial cell loss after one year was low, indicating favorable preliminary endothelial safety outcomes in the study population.
The Role of Electronic Calipers in ICL Sizing
Based on the study findings, the authors emphasized the role of the electronic caliper in measuring WTW. According to the study’s conclusions, the Caliper was considered the gold standard in this research context, helping minimize measurement errors in determining horizontal corneal diameter and supporting appropriate ICL sizing.
This also provides an important message for refractive surgeons: ICL sizing should not be based solely on myopia, astigmatism, or other refractive parameters, but should also take multiple anatomical factors into consideration. Accurate preoperative measurement and assessment can play an important role in optimizing ICL positioning and maintaining a safe Vault distance.
Phakic ICL – An Option for Patients with High Myopia and Astigmatism
Not every patient with myopia is suitable for laser refractive surgery. For patients with high myopia, thin corneas, or other characteristics that make corneal surgery less suitable, Phakic ICL may be considered following a comprehensive ophthalmic evaluation.
Unlike laser refractive procedures that reshape the cornea, ICL is implanted inside the eye while the natural crystalline lens is preserved.
Therefore, a comprehensive preoperative assessment should include:
- Assessment of refractive status and refractive stability.
- Measurement and evaluation of ocular anatomical parameters.
- Assessment of anterior chamber depth.
- Evaluation of endothelial cell density.
- Assessment of the anterior chamber angle.
- WTW measurement and appropriate ICL sizing.
- Comprehensive evaluation of overall ocular health before surgery.
What Does Dr. Nguyen Phu Tung’s Research Mean for Clinical Practice?
An important aspect of the research presented at HOOC5 is not only its postoperative visual outcomes but also its focus on the accuracy of the parameters used before selecting an ICL. A successful refractive procedure depends not only on the surgical technique but begins with comprehensive examination, accurate measurements, and appropriate lens selection for each individual patient.
The 12-month follow-up results indicate that V4c ICL provided favorable treatment efficacy, safety, and stability in the study population. At the same time, differences among WTW measurement devices highlight the need for caution when using measurements from different devices to determine appropriate ICL size.